Dimensions and Physical Characteristics of Copper Tube : DWV (Drain, Waste and Vent)

Dimensions and Physical Characteristics of Copper Tube : DWV (Drain, Waste and Vent)

Norminal or
Standards Sizes
Outside
Diameter
inside
Diameter
Wall
Thickness
Safe Working
Pressure in
inch.
Working
Pressure
Hard Drawn
Weight
Nom Size
O.D Size
mm.
mm.
inch
mm.
p.s.l.T
(kg/cm2)
(Kg./M)
1/4
1 3/8
34.525
32.885
0.04
1.02
1950
1.22
0.968
1 1/2
1 5/8
41.275
39.135
0.042
1.07
1740
1.62
1.205
2
2 1/8
53.975
51.335
0.042
1.07
1310
2.48
1.585
3
3 1/8
79.375
77.095
0.045
1.14
950
4.81
2.497
4
4 1/8
104.775
104.835
0.058
1.47
900
8.31
4.263
5
5 1/8
130.175
126.515
0.072
1.83
910
12.9
6.593
6
6 1/8
155.575
151.533
0.083
2.11
890
18.2
9.089
8
8 1/8
206.375
200.835
0.109
2,77
780
31.8
15.831

 

NOTE

Information and date contained in these charts as taken from ASTM Specifications No. B88. Federal Specification WW-T-799, and various Copper Tube Mill chart standards.

T Based upon 150 F. with an allowable stress of 9000 p.s.l.
* Bursting pressures.ard calculated from the following Formula for thin, hollow, cylinders under tension :

Where

P = 2ts/D

P = Bursting pressure, lb. Per sq. in
T = Wall thickness, inches
D = Outside tube diameter, inches
S = Tensile strenght (36,000 ib, Per sq. in. for haed tube and 30,000 for soft tubes)

* Based upon 150 F, with as allowable stress of 5100 p.s.l.